Frauscher Product Security Incident Response Team
Safety & Security
Frauscher PSIRT

We at Frauscher stand for safety in rail transport and individual solutions for our customers. That is why we have introduced a process for security-relevant topics, which helps us to react as quickly as possible to alleged security risks. We work according to a comprehensive approach to secure our products, services and individual solutions. 

For this purpose, we have established our Product Security Incident Response Team (PSIRT). You can reach our experts via the contact options listed at the bottom of the page.

How does it work?

Reporting

When you report a potential security risk to our experts, you will receive a confirmation from our Product Security Incident Response Team after a careful review.

Expert analysis

The potential risk will be analysed closely by our experts. If desired, you will receive regular status reports on the progress of the analysis.

Implementation

In this step, any necessary immediate measures are implemented, and long-term measures are planned.

Publication

The publication of the results and measures will be available on this page.

Security Advisory

Publication Date: 11.12.2023

CVE-ID: CVE-2023-5500 
CVSS v3.1 Base Score: 8.8 
CVSS Vector: AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CWE-ID: CWE-94

Summary
Frauscher Sensortechnik GmbH FDS102 for FAdC/FAdCi v2.10.1 is vulnerable to a remote code execution (RCE) vulnerability via manipulated parameters of the web interface by using an authenticated session cookie. 
This could lead to a full compromise of the FDS102 device.

Affected versions
v2.10.0 and v2.10.1 FDS102 versions

Mitigation
Security-related application conditions SecRAC
The railway operator must ensure that only authorised personnel or people in the company of authorised personnel have access to the Frauscher Diagnostic System FDS102.
The recommendation is to connect the Frauscher Diagnostic System FDS102 to a network of category 2. If the Frauscher Diagnostic System FDS102 is connected to a network of category 3 
(according to EN 50159:2010), then additional protective measures must be added.

Remediation
Update to FDS102 v2.10.2 or higher

Publication Date: 21.09.2023

CVE-ID: CVE-2023-4291 
CVSS v3.1 Base Score: 9.8 
CVSS Vector: AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CWE-ID: CWE-94

Summary
Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a remote code
execution (RCE) vulnerability via manipulated parameters of the web interface without authentication. This could lead to a full
compromise of the FDS101 device.

Affected versions
v1.4.24 and all previous FDS101 versions

Mitigation
Security-related application conditions SecRAC
The railway operator must ensure that only authorised personnel or people in the company of authorised personnel have access to the Frauscher Diagnostic System FDS101.
The recommendation is to connect the Frauscher Diagnostic System FDS101 to a network of category 2. If the Frauscher Diagnostic System FDS101 is connected to a network of category 3 
(according to EN 50159:2010), then additional protective measures must be added.

Remediation
Update to FDS102 v2.10.1 or higher

Publication Date: 21.09.2023

CVE-ID: CVE-2023-4152
CVSS v3.1 Base Score: 7.5 
CVSS Vector: AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
CWE-ID: CWE-22

Summary
Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a path traversal
vulnerability of the web interface by a crafted URL without authentication. This enables an remote attacker to read all files on the
filesystem of the FDS101 device.

Affected versions
v1.4.24 and all previous FDS101 versions

Mitigation
Security-related application conditions SecRAC
The railway operator must ensure that only authorised personnel or people in the company of authorised personnel have access to the Frauscher Diagnostic System FDS101.
The recommendation is to connect the Frauscher Diagnostic System FDS101 to a network of category 2. If the Frauscher Diagnostic System FDS101 is connected to a network of category 3 
(according to EN 50159:2010), then additional protective measures must be added.

Remediation
Update to FDS102 v2.10.1 or higher

Publication Date: 21.09.2023

CVE-ID: CVE-2023-4292
CVSS v3.1 Base Score: 5.3
CVSS Vector: AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
CWE-ID: CWE-89

Summary
Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a SQL injection
vulnerability via manipulated parameters of the web interface without authentication. The database contains limited, non-critical
log information.

Affected versions
v1.4.24 and all previous FDS101 versions

Mitigation
Security-related application conditions SecRAC
The railway operator must ensure that only authorised personnel or people in the company of authorised personnel have access to the Frauscher Diagnostic System FDS101.
The recommendation is to connect the Frauscher Diagnostic System FDS101 to a network of category 2. If the Frauscher Diagnostic System FDS101 is connected to a network of category 3 
(according to EN 50159:2010), then additional protective measures must be added.

Remediation
Update to FDS102 v2.10.1 or higher

Publication Date: 05.07.2023

CVE-ID: CVE-2023-2880
CVSS v3.1 Base Score: 7.5
CVSS Vector: AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
CWE-ID: CWE-22

Summary
Frauscher Sensortechnik GmbH FDS001 for FAdC/FAdCi v1.3.3 and all previous versions are vulnerable to a path traversal vulnerability of the web interface by a crafted URL without authentication. This enables a remote attacker to read all files on the filesystem of the FDS001 device.

Note: Orphaned SSH keys exist on the file system, but they cannot be used to log in to the machine.

Affected versions
v1.3.3 and all previous versions

Mitigation
Security-related application conditions SecRAC

The railway operator must ensure that only authorised personnel or people in the company of authorised personnel have access to the Frauscher Diagnostic System FDS001.

The recommendation is to connect the Frauscher Diagnostic System FDS001 to a network of category 2. If the Frauscher Diagnostic System FDS001 is connected to a network of category 3 (according to EN 50159:2010), then additional protective measures must be added.

Remediation
For the Frauscher Diagnostic System FDS001 for FAdC R1 and FAdCi R1 no more firmware updates will be provided.

Publication Date: 28.10.2022

CVE-ID: CVE-2022-3575
CVSS v3.1 Base Score: 9.8
CVSS Vector: AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CWE-ID: CWE-434

Summary
FDS102 for FAdC® R2 and FAdCi R2 v2.8.0 to v2.9.1 are vulnerable to malicious code upload without authentication by using the configuration upload function. This could lead to a complete compromise of the FDS102 device.

Affected versions
v2.8.0, v2.9.0, v2.9.1

Remediation
Update to v2.9.2 or higher

Publication Date: 15.12.2021

Summary

None of our Axle Counters and Wheel Sensors are affected (e.g. FAdC®, ACS2000, RSR110, RSR123, RSR180, ...).
None of our diagnostic products are affected (e.g. FDS, RMD, ASD, ...).

Contact Frauscher PSIRT

 